Results 1 - 8 de 8
Filter
1.
Rev. med. (Säo Paulo) ; 101(4): e-190105, jul.-ago. 2022.
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1392150

ABSTRACT

Objetivos. Avaliar o impacto da automação na fenotipagem eritrocitária expandida e o nível de concordância dessa com a metodologia manual em amostras de doadores de sangue atendidos no hemocentro coordenador da Fundação HEMOPA no período de janeiro a dezembro de 2019. Material e Métodos. Foram analisadas 2.700 fenotipagens eritrocitárias realizadas por metodologia manual e automatizada através do equipamento IH500 da BioRad®. Os resultados foram testados quanto ao nível de concordância através do teste de Coeficiente Kappa. Resultados. Das amostras fenotipadas 98,6% (2.662/2.700) foram concordantes em ambas as metodologias e apenas 1,4% (38/2700) foram discordantes. Das 38 amostras discordantes 31,6% referiram-se ao fenótipo Lu(b); 15,8% ao fenótipo Lu(a); 13,1% ao fenótipo Fy(b); 7,9% aos fenótipos Le(b), E, c; 5,3% aos fenótipos N, S, s, Kp(a), P1; e 2,6% aos fenótipos M, Jk(a), Jk(b), Fy(a). Conclusões. O nível de concordância entre os dados obtidos através das técnicas de fenotipagem eritrocitária manual e automatizada foi de 98,6%. Já a implantação dessa metodologia teve um impacto positivo com o aumento em 1.649 amostras processadas a mais em relação ao mesmo período do ano anterior. [au]


Objective. Evaluate the impact of automation on expanded erythrocyte phenotyping and the level of agreement between it and the manual methodology in samples from blood donors treated at the blood center coordinating the Fundação HEMOPA from january to december 2019. Material and Methods. 2,700 erythrocyte phenotyping performed by manual and automated methodology using BioRad® IH500 equipment was analyzed. The results were tested for the level of agreement using the Kappa Coefficient test. Results. Of the phenotyped samples, 98,6% (2,662 / 2,700) were in agreement in both methodologies and only 1,4% (38/2700) were in disagreement. Of the 38 discordant samples, 31,6% referred to the Lu(b) phenotype; 15,8% to the Lu(a) phenotype; 13,1% to the Fy phenotype (b); 7,9% to Le(b), E, c phenotypes; 5,3% to N, S, s, Kp (a), P1 phenotypes; and 2,6% for phenotypes M, Jk(a), Jk(b), Fy(a). Conclusions. The level of agreement between data obtained through manual and automated erythrocyte phenotyping techniques was 98.6%. The implementation of this methodology had a positive impact, with an increase of 1,649 more processed samples compared to the same period of the previous year. [au]

2.
J. Bras. Patol. Med. Lab. (Online) ; 55(3): 267-280, May-June 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1012485

ABSTRACT

ABSTRACT Introduction: Diagnosing infections in intensive care unit (ICU) patients is vital to provide appropriate therapies. Hematological analyzers perform automated immature granulocyte counts (IG) quickly and with no additional cost when compared to traditional microbiological cultures. Elevated IG is directly associated with infections and inflammation. Objectives: Evaluate IG as infection marker in adult inpatients at the ICU-Complexo Hospital de Clínicas da Universidade Federal do Paraná (CHC-UFPR), compared to cultures of biological materials (gold standard). Material And Methods: Samples of 200 adult inpatients at CHC-UFPR ICU with suspected infection were used. Absolute (IG#) and relative (IG%) counts were performed on the Sysmex XN-3000. Cultures and blood cultures were performed either manually or on Bactec FX. Diagnostic accuracy and agreement for IG# and IG% were evaluated. Results: The reference intervals (RI) obtained for IG# and IG% were 0.06 × 103/µl and 0.6%, respectively, with sensitivity for both of 74.4% and specificity of 25.3% for IG#, and 26.6% for IG%. The receiver operating characteristic (ROC) curve showed cut-off value of 0.33 × 103/µl for IG#, sensitivity of 28%, specificity of 82.3%, and area under the curve (AUC) of 0.521. For IG%, cut-off value was 1.35%, sensitivity 44.6%, specificity 64.6%, and AUC 0.532. CV < 3% increased specificity to 88%. Conclusion: RI of IG% and IG# showed high sensitivity and are useful in screening for infection in ICU patients. The CVs demonstrated by the ROC curves showed high specificity and are helpful on the exclusion of sepsis diagnosis in ICU patients. IG was shown to be useful for screening and confirmation of infection in ICU patients.


RESUMEN Introducción: Diagnosticar infecciones en pacientes de la unidad de cuidados intensivos (UCI) es de suma importancia para proporcionar el tratamiento adecuado. El contaje automatizado de granulocitos inmaduros (GI) en analizadores hematológicos es rápido y sin costes adicionales. La elevada tasa de GI está asociada a infecciones. Objetivos: Evaluar GI como indicador de infección en pacientes adultos de la UCI del Complexo Hospital de Clínicas da Universidade Federal do Paraná (CHC-UFPR) en comparación a culturas de materiales biológicos (estándar de oro). Material Y Métodos: Se analizaron muestras de 200 pacientes adultos con sospecha de infección de la UCI del CHC-UFPR. Los conteos automatizados de granulocitos inmaduros absolutos (GI#) e relativos (GI%) se realizaron en el Sysmex-XN-3000, y los cultivos y hemocultivos, manualmente o en el Baetec-FX. Se han evaluado precisión diagnóstica y concordancia para GI# y GI%. Resultados: Los rangos de referencia obtenidos para GI# y GI% fueron 0,06 × 103/µl y 0,6%, respectivamente, con sensibilidad para ambos de 74,4% y especificidad de 25,3% para IG# y 26,6% para IG%. La curva receiver operating characteristic (ROC) ha mostrado valor de corte de 0,33 × 103/µl para IG#, sensibilidad de 28%, especificidad de 82,3% y área bajo la curva (AUC) de 0,521. Para GI%, el valor de corte ha sido 135%, sensibilidad de 44,6%, especificidad de 64,6% y AUC de 0,532. Valores de corte de GI% < 3% aumentaron la especificidad para 88%. Conclusión: Rangos de referencia de GI% y GI# presentaron sensibilidad elevada y son útiles en el triaje de infecciones en pacientes de UCI. Los valores de corte enseñados por las curvas ROC presentaron alta especificidad, permitiendo la identificación adecuada de los pacientes sanos. GI se ha mostrado útil para triaje y confirmación de infección en pacientes de UCI.


RESUMO Introdução: Diagnosticar infecções em pacientes da unidade de terapia intensiva (UTI) é vital para implementar terapias apropriadas. A contagem automatizada de granulócitos imaturos (IG) em analisadores hematológicos é rápida e sem custos adicionais. A taxa de IG elevada está associada a infecções. Objetivos: Avaliar IG como indicador de infecção em pacientes adultos da UTI do Complexo Hospital de Clínicas da Universidade Federal do Paraná (CHC-UFPR) em comparação com culturas de materiais biológicos (padrão-ouro). Material E Métodos: Foram analisadas amostras de 200 pacientes adultos com suspeita de infecção da UTI do CHC-UFPR. As contagens automatizadas de granulócitos imaturos absolutas (IG#) e relativas (IG%) foram realizadas no Sysmex-XN-3000, e as culturas e as hemoculturas, manualmente ou no Bactec-FX. As características de desempenho de teste diagnóstico para IG# e IG% foram avaliadas. Resultados: Os intervalos de referência (IR) obtidos para IG# e IG% foram 0,06 × 103/µl e 0,6%, respectivamente, com sensibilidade para ambos de 74,4% e especificidade de 25,3% para IG# e 26,6% para IG%. A curva receiver operating characteristic (ROC) mostrou valor de corte de 0,33 × 103/µl para IG#, sensibilidade de 28%, especificidade de 82,3% e área sob a curva (AUC) de 0,521. Para IG%, o valor de corte foi de 1,35%, sensibilidade de 44,6%, especificidade de 64,6% e AUC de 0,532. Valores de corte de IG% < 3% aumentaram a especificidade para 88%. Conclusão: IRs de IG% e IG# apresentaram sensibilidade elevada e são úteis na triagem de infecção nos pacientes da UTI. Os VCs demonstrados pelas curvas ROC para IG% e IG# apresentaram elevada especificidade, sendo, portanto, úteis para exclusão de diagnóstico de sepse nos pacientes da UTI. IG mostrou-se útil para triagem e confirmação de infecção em pacientes de UTI.

3.
J. Bras. Patol. Med. Lab. (Online) ; 54(3): 158-163, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-954388

ABSTRACT

ABSTRACT Introduction: The harmonization of equipment is recommended in clinical laboratory practice aiming for the homogeneity of results when similar or equivalent analyzers are used to perform routine testing. Objectives: To conduct a study of equivalence between the biochemical analyzers Labmax 240® (E1) and Labmax 240 Premium® (E2) through the matching results and the statistical value analysis of dosages. Materials and methods: We evaluated tests with glucose, total cholesterol, triglycerides, uric acid, aspartate transaminase (AST), alanine transaminase (ALT) and lactate dehydrogenase (LDH), all with 40 repeated measurements, performed in both equipments. The Clinical and Laboratory Standards Institute (CLSI) EP09-3A protocol was used to conduct the comparison test between E1 and E2 equipment, with subsequent evaluation of the results for statistical analysis determining the Pearson correlation coefficient (r) and indexes comparison error with EP Evaluator® software. Results: Regarding the values of the Pearson correlation coefficient, all tests showed a strong correlation between equipment with r > 0.989, except for the dosage of LDH (r = 0.982). This dosage failed not because the value of r, but due to the values obtained in the error index being larger than the total errors index allowed. Discussion: Compared to clinical criteria, the results of the analyzers are approximately equal, but this control process must be done continuously in order to prevent and track random errors within the laboratory routine. Conclusion: The process of harmonization of multiple devices that perform the same laboratory parameters is essential for ensuring quality and reliability of laboratory results and should be standardized and included in routine clinical analysis laboratories.


RESUMO Introdução: No laboratório clínico, é recomendável a harmonização de equipamentos que visem à homogeneidade dos resultados, quando analisadores similares ou equivalentes são utilizados para desempenho da rotina de realização dos testes. Objetivos: Realizar um estudo de equivalência entre os analisadores bioquímicos Labmax 240® (E1) e Labmax 240 Premium® (E2). Materiais e métodos: Foram avaliados os testes glicose (GLI), colesterol total (COL), triglicerídeos (TRI), ácido úrico , aspartato aminotransferase (AST), alanina aminotransferase (ALT) e lactato desidrogenase (LDH), todos com 40 dosagens repetidas, realizadas em ambos os equipamentos. O protocolo do Clinical and Laboratory Standards Institute (CLSI) EP09-3A foi utilizado para conduzir o teste de comparação, com posterior avaliação dos resultados pela análise estatística no software EP Evaluator®, com determinação do coeficiente de correlação de Pearson (r) e comparação de índices de erro. Resultados: Em relação aos valores do coeficiente de correlação de Pearson, todos os testes apresentaram forte correlação entre os equipamentos, com r > 0,989, exceto para a dosagem de LDH (r = 0,982), que foi reprovada, não em função do valor de r, mas devido aos valores obtidos em relação ao índice de erro, o qual é maior do que os índices de erro total permitido. Discussão: Diante dos critérios clínicos, os resultados dos analisadores são aproximadamente iguais, porém esse controle do processo deve ser feito continuamente a fim de impedir e rastrear erros aleatórios dentro da rotina laboratorial. Conclusão: O processo de harmonização de múltiplos equipamentos que realizam os mesmos parâmetros laboratoriais é fundamental para a garantia da qualidade e da confiabilidade dos resultados laboratoriais, devendo ser padronizado e incluído na rotina dos laboratórios de análises clínicas.

4.
J. Bras. Patol. Med. Lab. (Online) ; 53(6): 382-387, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-893584

ABSTRACT

ABSTRACT Introduction: Pseudothrombocytopenia is an important source of pre-analytical problems in clinical laboratory; therefore it must be correctly evaluated. Low spurious platelet counts can lead to misdiagnosis. Objective: This study aims to study the resolution of pseudothrombocytopenia in the laboratory routine of clinical laboratory by standardizing the use of vortexer. Methods: This is a cross-sectional, analytical, quantitative study based on experimental approach, involving 45 pseudothrombocytopenia samples divided into three groups and submitted to vortexing for 1, 2 and 3 minutes. Results: During the study, 28,435 blood counts were performed, and 56 (0.196%) of these samples confirmed platelet aggregates. The 2 and 3 minute times normalized the platelet count (greater than 150,000/µl) in two thirds of the samples tested. Platelets, hemolysis index, platelet distribution width (PDW) and mean platelet volume (MPV) presented statistically significant mean difference (MD) (p < 0.05) after vortexing at all times. Conclusion: The 2 and 3-minute times were the most effective in the resolution of pseudothrombocytopenia, however, the 2 minutes time should be preferred because it produced fewer effects on the erythrocyte membrane.


RESUMO Introdução: A pseudotrombocitopenia constitui importante fonte de problemas pré-analíticos no laboratório clínico, por isso deve ser corretamente avaliada. Baixas contagens de plaquetas espúrias podem levar a suspeitas diagnósticas equivocadas. Objetivo: Este estudo se propôs a estudar a resolução da pseudotrombocitopenia na rotina de laboratório de análises clínicas pela padronização do uso de vortex. Métodos: Trata-se de um estudo transversal analítico e quantitativo, apresentando-se dentro de uma abordagem de cunho experimental, o qual envolveu 45 amostras pseudotrombocitopênicas divididas em três grupos e submetidas a agitação com vortex nos tempos de 1, 2 e 3 minutos. Resultados: Durante a realização do estudo, foram realizados 28.435 hemogramas, sendo 56 (0,196%) amostras confirmadas com a presença de agregados plaquetários. Os tempos de 2 e 3 minutos normalizaram a contagem de plaquetas (maior que 150.000/µl), em dois terços das amostras testadas. Plaquetas, índice de hemólise, amplitude de distribuição das plaquetas (PDW) e volume plaquetário médio (VPM) apresentaram diferença de média estatisticamente significativa (p < 0,05) após o tratamento com vortex em todos os tempos testados. Conclusão: Os tempos de 2 e 3 minutos foram os mais eficazes na resolução da pseudotrombociopenia, contudo, o tempo de 2 minutos deve ser utilizado por ter produzido menores efeitos sobre a membrana eritrocitária.

5.
J. Bras. Patol. Med. Lab. (Online) ; 53(3): 150-158, May.-June 2017. tab, graf
Article in English | LILACS | ID: biblio-954366

ABSTRACT

ABSTRACT Introduction: Body fluid (BF) analysis is critical to the diagnosis and monitoring of several pathological conditions. The limitations of manual cell counts have led to greater interest in the development of automated BF analysis. Objective: To evaluate the analytical performance of the Sysmex XE-5000 hematology analyzer in the analysis of pleural and ascitic fluids in the laboratory routine of a large university hospital. Methods: A total of 56 samples (35 ascitic and 21 pleural fluids) were analyzed by manual optical microscopy (OM) and XE-5000. Analytical performance includes linearity, carryover, functional sensitivity and comparison of patient samples. Results: Performance studies showed linearity up to 25,825 WBC-BF/µl (r2 = 0.999), WBC-BF showed carryover of 0.18%, and the lower limit of quantitation was set at 22 WBC-BF/µl. Good correlations between the methods were observed just for total cell (TC-BF) and white blood cell (WBC-BF) counts in pleural and ascitic fluids. The high-fluorescence cell count (HF-BF) showed poor correlation but high positive predictive value (PPV) for both fluids (94.74% for pleural and 96.97% for ascitic fluid). Conclusion: XE-5000 provides accurate and precise count for TC-BF, WBC-BF and polymorphonuclear cells (PMN-BF) in pleural and ascitic fluids in medical decision levels, but the morphological differentiation should continue to be held by OM. Histogram and scattergram displayed on XE-5000 must always be analyzed to assess if there is any interference or flag. The HF-BF parameter is a potential tool for screening.


RESUMO Introdução: A análise de líquidos corporais é fundamental para o diagnóstico e o acompanhamento de várias condições patológicas. Devido às limitações da contagem manual de células, tem ocorrido maior interesse no desenvolvimento da análise automatizada de líquidos corporais. Objetivo: Verificar o desempenho analítico do analisador hematológico Sysmex XE-5000 na análise de fluidos pleurais e ascíticos na rotina laboratorial de um hospital universitário de grande porte. Métodos: Um total de 56 amostras (35 de líquidos ascíticos e 21 de líquidos pleurais) foi analisado por microscopia ótica manual (MOM) e pelo XE-5000. O estudo de verificação incluiu linearidade, carryover, limite de quantificação e comparação de amostras de pacientes. Resultados: O estudo de verificação mostrou linearidade de até 25.825 WBC-BF/ml (r2 = 0,999); WBC-BF, carryover de 0,18%; e o menor limite de quantificação foi fixado em 22 WBC-BF/ml. Boas correlações entre o método manual e o automatizado foram observadas apenas para as contagens de total de células nucleadas (TC-BF) e glóbulos brancos (WBC-BF) em líquidos pleurais e ascíticos. A contagem de células de alta fluorescência (HF-BF) mostrou correlação fraca, porém valor preditivo positivo (VPP) elevado para ambos os líquidos corporais (94,74% pleural; 96,97% ascítico). Conclusão: O XE-5000 fornece contagem confiável para TC-BF, WBC-BF e células polimorfonucleares (PMN-BF) em fluidos pleurais e ascíticos em níveis de decisão médica, contudo a diferenciação morfológica deve continuar a ser realizada por MOM. O histograma e o diagrama de dispersão exibidos no XE-5000 devem ser sempre avaliados quanto à existência de qualquer interferência ou alerta suspeito. A contagem de HF-BF constitui uma potencial ferramenta para triagem.

6.
Dental press j. orthod. (Impr.) ; 20(4): 45-50, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-757423

ABSTRACT

OBJECTIVE: The aim of this study was to assess whether repetitive opening and closure of self-ligating bracket clips can cause plastic deformation of the clip.METHODS: Three types of active/interactive ceramic self-ligating brackets (n = 20) were tested: In-Ovation C, Quicklear and WOW. A standardized controlled device performed 500 cycles of opening and closure movements of the bracket clip with proper instruments and techniques adapted as recommended by the manufacturer of each bracket type. Two tensile tests, one before and one after the repetitive cycles, were performed to assess the stiffness of the clips. To this end, a custom-made stainless steel 0.40 x 0.40 mm wire was inserted into the bracket slot and adapted to the universal testing machine (EMIC DL2000), after which measurements were recorded. On the loading portion of the loading-unloading curve of clips, the slope fitted a first-degree equation curve to determine the stiffness/deflection rate of the clip.RESULTS: The results of plastic deformation showed no significant difference among bracket types before and after the 500 cycles of opening and closure (p = 0.811). There were significant differences on stiffness among the three types of brackets (p = 0.005). The WOW bracket had higher mean values, whereas Quicklear bracket had lower values, regardless of the opening/closure cycle.CONCLUSION: Repetitive controlled opening and closure movements of the clip did not alter stiffness or cause plastic deformation.


OBJETIVO: o objetivo deste estudo foi avaliar se a abertura e o fechamento repetitivo do clipe de braquetes autoligáveis podem causar deformação plástica do clipe.MÉTODOS: três tipos de braquetes autoligáveis ativos/interativos estéticos (n = 20) foram testados: In-Ovation C, Quicklear e WOW. Um dispositivo realizou, de forma controlada e padronizada, 500 ciclos de abertura e de fechamento do clipe, com instrumentos e técnicas adequadas, tal como recomendado pelo fabricante de cada tipo de braquete. Dois ensaios de tração, um antes e um depois dos ciclos repetitivos, foram realizados para se avaliar a rigidez dos clipes. Para o ensaio de tração, um fio de 0,40 x 0,40mm de aço inoxidável foi inserido no slot do braquete e adaptado em uma máquina universal de ensaios (EMIC DL2000), sendo as medições registradas. Na porção retilínea da curva de carregamento dos clipes, a inclinação é definida por uma equação de primeiro grau, determinando o coeficiente de elasticidade (rigidez) do clipe.RESULTADOS: os resultados quanto à deformação plástica não mostraram nenhuma diferença significativa entre os tipos de braquetes, antes e depois dos 500 ciclos de abertura e de fechamento (p = 0,811). Foram encontradas diferenças significativas na rigidez entre os três tipos de braquetes (p = 0,005): o braquete WOW demonstrou valores médios mais elevados, e o braquete Quicklear demonstrou valores mais baixos, independentemente do ciclo de abertura e fechamento.CONCLUSÃO: movimentos repetitivos controlados de abertura e de fechamento do clipe não alteraram a rigidez ou causaram deformação plástica.


Subject(s)
Ceramics/chemistry , Orthodontic Brackets , Orthodontic Appliance Design , Dental Alloys/chemistry , Dental Materials/chemistry , Orthodontic Wires , Stainless Steel/chemistry , Stress, Mechanical , Tensile Strength , Materials Testing , Pliability , Dental Stress Analysis/instrumentation , Mechanical Phenomena , Elastic Modulus
7.
J. bras. patol. med. lab ; 49(5): 324-331, Oct. 2013. ilus, tab
Article in English | LILACS | ID: lil-697107

ABSTRACT

INTRODUCTION AND OBJECTIVE: To evaluate the performance of red cell distribution width reported statistically as coefficient of variation (RDW-CV), standard deviation (RDW-SD), and mathematical deduction of 1 standard deviation (SD) around mean corpuscular volume (MATH-1SD) in identifying anisocytosis in automated blood counts when compared with the manual quantification of erythrocyte anisocytosis in peripheral blood smears. MATERIAL AND METHODS: 806 routine samples obtained from the hematology laboratory of Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR) were analyzed. Performance evaluations were carried out by dividing samples into microcytic, normocytic and macrocytic mean corpuscular volume (MCV). For each MCV range, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and efficiency were calculated. In addition, the Youden index (Y) was obtained and a comparative analysis with receiver operating characteristic (ROC) curves was done to evaluate the performance of RDW-SD, RDW-CV, and MATH-1SD on different MCV ranges. RESULTS AND DISCUSSION: RDW-CV had the best sensitivity (86.8%) and efficiency (86.8%) in detecting anisocytosis in microcytic MCV ranges. RDW-SD and MATH-1SD were more sensitive and efficient in normocytic (82.9% and 83.3%; 92.1% and 92.3%, respectively) and macrocytic (90.2% and 90.2%; 95.1% and 95.1%, respectively) MCV ranges. A ROC curve analysis indicated that RDW-CV was more efficient in detecting anisocytosis in microcytic MCV ranges (p < 0.05 vs. RDW-SD and MATH-1SD). In normocytic and macrocytic MCV ranges, RDW-SD and MATH-1SD showed similar efficiency in detecting anisocytosis (p < 0.05 vs. RDW-CV). CONCLUSION: RDW-SD, RDW-CV, and MATH-1SD deliver different performances in detecting blood smear anisocytosis according to MCV values. They are parameters that complement each other and should be used together to identify erythrocyte size heterogeneity.


INTRODUÇÃO E OBJETIVO: Avaliar o desempenho do red cell distribution width expresso em coeficiente de variação (RDW-CV) e desvio padrão (RDW-SD) e da dedução matemática de 1 desvio padrão (DP) ao redor do volume corpuscular médio (MATH-1SD) ao identificar anisocitose nos hemogramas automatizados, quando comparados com o método manual de quantificação da anisocitose eritrocitária em lâmina. MATERIAL E MÉTODOS: Foram analisadas 806 amostras obtidas da rotina laboratorial da Seção de Hematologia do Hospital de Clínicas da Universidade Federal do Paraná (HC-UFPR). As avaliações de desempenho foram realizadas dividindo-se as amostras em volume corpuscular médio (VCM) microcítico, VCM normocítico e VCM macrocítico. Para cada faixa de VCM, sensibilidade, especificidade, valor preditivo positivo (VPP), valor preditivo negativo (VPN) e eficiência foram determinados. Além disso, o índice de Youden foi calculado e uma análise comparativa de curvas de características de operação do receptor (curvas ROC [receiver operating characteristic]) foi realizada para verificar o desempenho de RDW-CV, RDW-SD e MATH-1SD em diferentes faixas de VCM. RESULTADOS E DISCUSSÃO: O RDW-CV obteve a melhor sensibilidade (86,8%) e eficiência (86,8%) ao detectar anisocitose em faixas de VCM microcítico. O RDW-SD e o MATH 1SD foram mais sensíveis e eficientes em VCM normocítico (82,9% e 83,3%; 92,1% e 92,3%, respectivamente) e macrocítico (90,2% e 90,2%; 95,1% e 95,1%, respectivamente). A comparação de curvas ROC demonstrou que o RDW-CV foi mais eficiente ao detectar anisocitose em VCM microcítico (p < 0,05 vs. RDW-SD e MATH-1SD). Em VCM normocítico e macrocítico, o RDW-SD e o MATH-1SD mostraram eficiência semelhante ao detectar anisocitose (p < 0,05 vs. RDW-CV). CONCLUSÃO: RDW-CV, RDW-SD e MATH-1SD possuem desempenhos diferentes ao detectar anisocitose em lâmina conforme a faixa de VCM. São parâmetros que se complementam e que devem ser utilizados em conjunto na identificação de heterogeneidade dos tamanhos eritrocitários.

8.
Rev. saúde pública ; 46(3): 456-465, jun. 2012. tab
Article in English, Portuguese | LILACS | ID: lil-625672

ABSTRACT

OBJETIVO: Elaborar indicadores de desempenho e terceirização em rede de laboratórios clínicos, baseados em sistemas de informações e registros administrativos públicos. MÉTODOS: A rede tinha 33 laboratórios com equipamentos automatizados, mas sem informatização, 90 postos de coleta e 983 funcionários, no município de Rio de Janeiro, RJ. As informações foram obtidas de registros administrativos do Sistema de Informações de Orçamentos Públicos para a Saúde e do Sistema de Informações Ambulatoriais e Hospitalares do Sistema Único de Saúde. Os indicadores (produção, produtividade, utilização e custos) foram elaborados com dados colhidos como rotina de 2006 a 2008. As variações da produção, custos e preços unitários dos testes no período foram analisadas por índices de Laspeyres e de Paasche, específicos para medir a atividade dos laboratórios, e pelo Índice de Preços ao Consumidor Amplo do Instituto Brasileiro de Geografia e Estatística. RESULTADOS: A produção foi de 10.359.111 testes em 2008 (aumento de 10,6% em relação a 2006) e a relação testes/funcionário cresceu 8,6%. As despesas com insumos, salários e prestador conveniado aumentaram, respectivamente 2,3%, 45,4% e 18,3%. Os testes laboratoriais por consulta e internação cresceram 10% e 20%. Os custos diretos totalizaram R$ 63,2 milhões em 2008, com aumento de 22,2% em valores correntes no período. Os custos diretos deflacionados pelo Índice de Preços ao Consumidor Amplo (9,5% para o período) mostram aumento do volume da produção de 11,6%. O índice de volume específico para a atividade, que considera as variações do mix de testes, mostrou aumento de 18,5% no preço unitário do teste e de 3,1% no volume da produção. CONCLUSÕES: Os indicadores, em especial os índices específicos de volume e preços da atividade, constituem uma linha de base de desempenho potencial para acompanhar laboratórios próprios e terceirizados. Os indicadores de desempenho econômicos elaborados mostram a necessidade de informatização da rede, antecedendo a decisão de terceirização.


OBJECTIVE: To develop performance indicators for outsourcing clinical laboratory services, based on information systems and public administrative records. METHODS: In the municipality of Rio de Janeiro, Southern Brazil, the public health laboratory network comprised 33 laboratories with automated equipment (but no integrated information system), 90 primary care units (where sample collection was performed) and 983 employees. Information records were obtained from the administrative records of the Budget Information System for Public Health and the Outpatient and Hospital Information System of the Unified Health System. Performance indicators (production, productivity, usage and costs) were generated from data collected routinely from 2006 to 2008. The variations in production, costs and unit prices for tests were analyzed by Laspeyres and Paasche indices, which specifically measure laboratory activity, and by the Consumer Price Index from the Brazilian Institute of Geography and Statistics. RESULTS: A total of 10,359,111 tests were performed in 2008 (10.6% increase over 2006), and the test/employee ratio grew by 8.6%. The costs of supplies, wages and providers increased by 2.3%, 45.4% and 18.3%, respectively. The laboratory tests per visit and hospitalizations increased by 10% and 20%, respectively. The direct costs totaled R$ 63.2 million in 2008, representing an increase of 22.2% in current values during the period analyzed. The direct costs deflated by the Brazilian National Consumer Price Index (9.5% for the period) showed an 11.6% increase in production volumes. The activity-specific volume index, which considers changes in the mix of tests, showed increases of 18.5% in the test price and 3.1% in the production volume. CONCLUSIONS: The performance indicators, particularly the specific indices for volume and price of activity, constitute a baseline of performance potential for monitoring private laboratories and contractors. The economic performance indicators demonstrated the need for network information system integration prior to an outsourcing decision.


Subject(s)
Humans , Laboratories/economics , Outsourced Services/economics , Quality Indicators, Health Care , Brazil , Decision Making , Laboratories/organization & administration , Laboratories/standards , Outsourced Services/organization & administration , Outsourced Services/standards